Scaffolding & Electrical Conduit Tubes

PRODUCT CATALOGUE

Steel Tubes for Scaffolding

Mechanical Properties

Tensile 340 N/mm² to 460N/mm²
Yield Strength 210 N/mm² min
Elongation 22%min

Chemical Composition

C 0.20% max
Si 0.30% max
P 0.060% min
S 0.060% min
Dimensions and Tolerance for Welded Steel Tubes
Parameter Dimensions and Mass Tolerance
Outside Diameter(OD) 48.3mm ± 0.5mm
Thickness(T) 4.0mm Welded Tube +0.8mm -0.4mm
Nominal mass per unit length 4.37Kg/mtr Single Tube Max -7.5%
Quantities of 150m and over ± 4%
Length if specified exact otherwise ± 6.0mm Random length of 4 to 7 Mtr.
Straightness - 1/600 of length

Electrical Conduit

Nominal Size Outside Diameter(OD) Thickness(T) Weight(KG/Mtr.)
(mm) Min Max (mm) Class 1,2&3 Class 4
Min Max Min Max
16 15.7 16.0 1.0+0.10
1.4+0.10
0.324
0.452
0.405
0.531
0.355
0.483
0.470
0.594
20 19.7 20.0 1.0+0.10
1.6+0.15
0.416
0.643
0.515
0.783
0.457
0.682
0.597
0.862
25 24.6 25.0 1.2+0.15
1.6+0.15
0.598
0.811
0.784
0.995
0.649
0.860
0.887
1.095
32 31.6 32.0 1.2+0.15
1.6+0.15
0.796
1.069
1.006
1.301
0.861
1.133
1.139
1.432